Bihl+Wiedemann

BWU3865 ASi-5/ASi-3 openSAFETY via POWERLINK Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters

ASi-5/ASi-3 openSAFETY via POWERLINK Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2 channels safe inputs,..

BWU3828 ASi-5/ASi-3 POWERLINK Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 Master

ASi-5/ASi-3 POWERLINK Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2 channels safe inputs, 1922 x 2 chann..

BWU3176 ASi-3 POWERLINK Gateway with integrated Safety Monitor, 2 ASi-3 masters

ASi-3 POWERLINK Gateway with integrated Safety Monitor, 2 ASi-3 masters, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2 channels safe inputs, 1922 x 2 channels safe inp..

BWU3177 ASi-3 POWERLINK Gateway with integrated Safety Monitor, 1 ASi-3 master

ASi-3 POWERLINK Gateway with integrated Safety Monitor, 1 ASi-3 master, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 31 x 2 channels safe inputs, 1891 x 2 channels safe inpu..

BWU3861 ASi-5/ASi-3 safe Schneider drives over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters

ASi-5/ASi-3 safe Schneider drives over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2 channels saf..

BWU3860 ASi-5/ASi-3 CIP Safety over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters

ASi-5/ASi-3 CIP Safety over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2 channels safe inputs, 1..

BWU3845 ASi-5/ASi-3 CIP Safety over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters

ASi-5/ASi-3 CIP Safety over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, expandable to max. 62 x 2 channels safe inputs, 1922 x 2 channels safe inputs in max. configuration, expandable t..

BWU2822 ASi-3 PROFIBUS Gateway with integrated Safety Monitor, 2 ASi-3 masters

ASi-3 PROFIBUS Gateway with integrated Safety Monitor, 2 ASi-3 masters, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2 channels safe inputs, 1922 x 2 channels safe inpu..

BWU2793 ASi-3 PROFIBUS Gateway with integrated Safety Monitor, 1 ASi-3 master

ASi-3 PROFIBUS Gateway with integrated Safety Monitor, 1 ASi-3 master, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 31 x 2 channels safe inputs, 1891 x 2 channels safe input..

BWU2819 ASi-3 PROFIsafe via PROFIBUS Gateway with integrated Safety Monitor, 1 ASi-3 master

ASi-3 PROFIsafe via PROFIBUS Gateway with integrated Safety Monitor, 1 ASi-3 master, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 31 x 2 channels safe inputs, 6 release circ..

BWU2804 ASi-3 CANopen Gateway with integrated Safety Monitor, 1 ASi-3 master

ASi-3 CANopen Gateway with integrated Safety Monitor, 1 ASi-3 master, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 31 x 2 channels safe inputs, 1891 x 2 channels safe inputs..

BWU2833 ASi-3 CC-Link Gateway with integrated Safety Monitor, 1 ASi-3 master

ASi-3 CC-Link Gateway with integrated Safety Monitor, 1 ASi-3 master, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 31 x 2 channels safe inputs, 1891 x 2 channels safe inputs..