Bihl+Wiedemann
BWU3349 Active Distributor ASi, IP20, 4I
Active Distributor ASi, IP20, housing depth 19 mm, 4 digital inputs, input voltage/sensor supply out of AUX, periphery connection via 8 x push in terminals, flat design, installation in cable duct possible (installation depth ≥ 19 mm), LED, connections for 1 x ASi and 1 x AUX profile cables, ASi con..
BWU3414 Active Distributor ASi, IP20, 3I/1O
Active Distributor ASi, IP20, housing depth 19 mm, 3 digital inputs, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 8 x push in terminals, flat design, installation in cable duct possible (installation depth ≥ 19 mm), LED..
BWU3342 Active Distributor ASi, IP20, 4O
Active Distributor ASi, IP20, housing depth 19 mm, 4 digital outputs, output voltage/actuator supply out of AUX, periphery connection via 8 x push in terminals, flat design, installation in cable duct possible (installation depth ≥ 19 mm), LED, connections for 1 x ASi and 1 x AUX profile cables, ASi..
BWU4386 ASi-5 Module with integrated IO-Link Master with 8 Ports, IP67, M12, 8 IO-Link ports class A
ASi-5 module with integrated IO-Link master in IP67, with 8 x M12 sockets, 8 x IO-Link ports class A, sensor supply (IO-Link supply and input/output supply) out of AUX, periphery connection via 8 x M12 sockets, 5 poles, ASi connection via profile cable and piercing technology, 1 ASi-5 address ..
BWU3819 ASi-5 Module with integrated IO-Link Master with 4 Ports, IP67, M12, 4 IO-Link ports class A
ASi-5 Module with integrated IO-Link Master in IP67, with 4 x M12 sockets, 4 x IO-Link ports class A, sensor supply (IO-Link supply and input/output supply) out of AUX, periphery connection via 4 x M12 sockets, 5 poles, ASi connection via profile cable and piercing technology, 1 ASi-5 address The su..
BWU3899 ASi-5 Module with integrated IO-Link Master with 4 Ports, IP67, M12, 4 IO-Link ports class A
ASi-5 Module with integrated IO-Link Master in IP67, with 4 x M12 sockets, 4 x IO-Link ports class A, sensor supply (IO-Link supply and input/output supply) out of AUX, periphery connection via 4 x M12 sockets, 5 poles, ASi connection via M12, 1 ASi-5 address ..
BWU4067 ASi-5 Module with integrated IO-Link Master with 4 Ports, IP67, M12, 2 IO-Link ports class A/2 IO-Link ports class B
ASi-5 Module with integrated IO-Link Master in IP67, with 4 x M12 sockets, 2 x IO-Link ports class A, 2 x IO-Link ports class B, sensor supply (IO-Link supply and input/output supply) out of AUX, actuator supply (for IO-Link ports class B) out of AUX, periphery connection via 4 x M12 sockets, 5 pole..
BWU3897 ASi-5 Module with integrated IO-Link Master with 4 Ports, IP67, M12, 2 IO-Link ports class A/2 IO-Link ports class B
ASi-5 Module with integrated IO-Link Master in IP67, with 4 x M12 sockets, 2 x IO-Link ports class A, 2 x IO-Link ports class B, sensor supply (IO-Link supply and input/output supply) out of AUX, actuator supply (for IO-Link ports class B) out of AUX, periphery connection via 4 x M12 sockets, 5 pole..
BWU4077 Active Distributor ASi-5/IO-Link Master with 2 Ports, IP67, M12, 1 IO-Link Port Class A/1 IO-Link Port Class B
Active Distributor ASi-5/IO-Link Master, IP67, housing depth 35 mm, 1 x IO-Link port class A, 1 x IO-Link port class B, sensor supply out of AUX, actuator supply out of AUX, periphery connection via 2 x M12 cable sockets, straight, 5 poles, cable length 1 m, flat design, installation in cable duct p..
BWU4748 Active Distributor ASi-5/IO-Link Master with 1 Port, IP67, M12, 1 IO-Link Port Class A
Active Distributor ASi-5/IO-Link Master, IP67, housing depth 35 mm, 1 x IO-Link port class A, sensor supply (IO-Link supply and input/output supply) out of ASi, periphery connection via 1 x M12 cable socket, straight, 5 poles, cable length 1 m, flat design, installation in cable duct possible (insta..
BWU4088 Active Distributor ASi-5/IO-Link Master with 1 Port, IP67, M12, 1 IO-Link Port Class B
Active Distributor ASi-5/IO-Link Master, IP67, housing depth 35 mm, 1 x IO-Link port class B, sensor supply out of AUX, actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 5 poles, cable length 1 m, flat design, installation in cable duct possible (installation d..
BWU3843 ASi-5 Module with integrated IO-Link Master with 4 Ports, IP20, 4 IO-Link Ports
ASi-5 Module with integrated IO-Link Master in IP20, 22,5 mm x 114 mm, with 6 x COMBICON connections, 4 x IO-Link ports with configurable conectors for port class A or port class B, sensor supply (IO-Link supply and input/output supply) out of AUX, periphery connection via clamps, ASi connection via..