Bihl+Wiedemann
BWU3852 ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 2 ASi-5/ASi-3 masters
ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 2 ASi-5/ASi-3 masters, OPC UA server, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, diagnostic and configuration via PROFINET or Ethernet diagnostic interface, duplicate address recognition, ASi fault detecto..
BWU4257 ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 2 ASi-5/ASi-3 masters
ASi-5/ASi-3 PROFINET gateway in stainless steel, 2 ASi-5/ASi-3 masters, OPC UA server, integrated decoupling, max. 8 A per ASi circuit, ASi current measurement in the gateway, diagnostic and configuration via PROFINET or Ethernet diagnostic interface, duplicate address recognition, ASi fault detecto..
BWU3847 24 Volt ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi-5/ASi-3 master
24 Volt ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi-5/ASi-3 master, OPC UA server, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, diagnostic and configuration via PROFINET, duplicate address recognition, ASi fault detector, IP20 ..
BWU3848 ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi-5/ASi-3 master
ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi-5/ASi-3 master, OPC UA server, integrated decoupling, max. 8 A per ASi circuit, ASi current measurement in the gateway, diagnostic and configuration via PROFINET or Ethernet diagnostic interface, duplicate address recognition, ASi fault detector..
BWU3972 24 Volt ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi-5/ASi-3 master
24 Volt ASi-5/ASi-3 PROFINET gateway in stainless steel, 1 ASi-5/ASi-3 master, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in gateway, diagnostic and configuration via PROFINET, duplicate address recognition, ASi fault detector, IP20 ..
BWU4818 ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi-5/ASi-3 Master
ASi-5/ASi-3 PROFINET gateway in stainless steel, 1 ASi-5/ASi-3 master, integrated decoupling, max. 8 A per ASi circuit, ASi current measurement in the gateway, diagnostic and configuration via PROFINET or Ethernet diagnostic interface, duplicate address recognition, ASi fault detector, programming i..
BWU3363ASi-3 PROFINET Gateway in Edelstahl, 2 Master
ASi-3 PROFINET Gateway in Stainless Steel, 2 ASi masters, 1 power supply for 2 ASi networks, diagnostic and configuration via PROFINET, duplicate address recognition, ASi fault detector, programming in C optional Fieldbus interface ..
BWU4855 ASi-3 PROFINET Gateway in Stainless Steel, 2 ASi-3 Masters
ASi-3 PROFINET gateway in stainless steel, 2 ASi-3 masters, integrated decoupling, max. 8 A per ASi circuit, ASi current measurement in the gateway, diagnostic and configuration via PROFINET or Ethernet diagnostic interface, duplicate address recognition, ASi fault detector, programming in C optiona..
BWU2919 24 Volt ASi-3 PROFINET Gateway in Stainless Steel, 1 master
24 Volt ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi master, 1 power supply for 2 ASi networks, diagnostic and configuration via PROFINET, duplicate address recognition, ASi fault detector, programming in C optional Fieldbus interface ..
BWU5021 ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi-3 master
ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi-3 master, integrated decoupling, max. 8 A per ASi circuit, ASi current measurement in the gateway, diagnostic and configuration via PROFINET or Ethernet diagnostic interface, duplicate address recognition, ASi fault detector, programming in C optional..
BWU2729 ASi-3 PROFINET Gateway in Stainless Steel, 1 master
ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi master, diagnostic and configuration via PROFINET, duplicate address recognition, ASi fault detector, programming in C optional Fieldbus interface ..
BWU3851 ASi-5/ASi-3 EtherNet/IP+ModbusTCP Gateway in Stainless Steel, 2 ASi-5/ASi-3 masters
ASi-5/ASi-3 EtherNet/IP + Modbus TCP Gateway in Stainless Steel, OPC UA server, 2 ASi-5/ASi-3 masters, integrated decoupling, max. 4 A per ASi circuit, ASi current measurement in the gateway, diagnostic and configuration via Ethernet/IP + Modbus TCP or Ethernet diagnostic interface, duplicate addres..