SM8004 - efector300-SMR11GGX50KG/US100
- Brand:IFM ELECTRONIC
- Product Code: SM8004
- Availability: Out Of Stock
- Precise measurement of flow, consumption and medium temperature
- High accuracy, repeatability and measurement dynamics
- With two precise analogue outputs
- Clearly visible 4-digit LED display
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 2 | ||
|---|---|---|---|
| Measuring range |
| ||
| Process connection | threaded connection G 1 DN25 flat seal |
Application
| Special feature | Gold-plated contacts | ||
|---|---|---|---|
| Application | for industrial applications | ||
| Installation | connection to pipe by means of an adapter | ||
| Media | conductive liquids; water; hydrous media | ||
| Note on media |
| ||
| Medium temperature [°C] | -10...70 | ||
| Pressure rating [bar] | 16 | ||
| Pressure rating [Mpa] | 1.6 | ||
| MAWP (for applications according to CRN) [bar] | 11.2 |
Electrical data
| Operating voltage [V] | 20...30 DC; (to SELV/PELV) |
|---|---|
| Current consumption [mA] | 120; (24 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 5 |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 2 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | analogue signal |
| Number of analogue outputs | 2 |
| Analogue current output [mA] | 4...20; (scalable) |
| Max. load [Ω] | 500 |
| Overload protection | yes |
Measuring/setting range
| Measuring range |
| ||
|---|---|---|---|
| Display range |
| ||
| Resolution |
| ||
| Analogue start point ASP |
| ||
| Analogue end point AEP |
| ||
| In steps of |
|
| Measuring range [°C] | -20...80 |
|---|---|
| Resolution [°C] | 0.2 |
| Analogue start point [°C] | -20...60 |
| Analogue end point [°C] | 0...80 |
| In steps of [°C] | 0.2 |
Accuracy / deviations
| Accuracy (in the measuring range) | ± (2 % MW + 0,5 % MEW) |
|---|---|
| Repeatability | ± 0,2% MEW |
| Accuracy [K] | ± 2,5 (Q > 1 l/min) |
|---|
Response times
| Response time [s] | 0.15; (dAP = 0, T19) |
|---|---|
| Damping process value dAP [s] | 0...3 |
| Dynamic response T05 / T09 [s] | T09 = 20 (Q > 1 l/min) |
|---|
Operating conditions
| Ambient temperature [°C] | -10...60 |
|---|---|
| Storage temperature [°C] | -25...80 |
| Protection | IP 67 |
Tests / approvals
| EMC |
| ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CPA approval |
| ||||||||||||
| Shock resistance |
| ||||||||||||
| Vibration resistance |
| ||||||||||||
| MTTF [years] | 175 | ||||||||||||
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight [g] | 576.9 |
|---|---|
| Materials | stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK; FKM |
| Process connection | threaded connection G 1 DN25 flat seal |
Displays / operating elements
| Display |
| ||||||
|---|---|---|---|---|---|---|---|
| Display unit | l/min; m³/h; gpm; gph; °C; °F |
Remarks
| Remarks |
| ||
|---|---|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
|---|
Diagrams and graphs
| Pressure loss |
|
|---|