Pepperl+Fuchs
Connector box CBX800
Connection module for RS-232 and RS-485 enabled devices, Easy scanner connection by means of clamp terminals, Degree of protection IP65, Option of upgrading with Profibus, Ethernet and DeviceNet module Datasheet excerpt: Technical data of CBX800 Product Description Connection module fo..
Thru-beam sensor (pair) M100/MV100-RT/35/76a/95/103
Thru-beam sensor, 20 m detection range, red light, light/dark on, DC version, PNP output, sensitivity adjuster, emitter switch-off, M8 plug, Miniature design, Easy to use, Very bright, highly visible light spot, Full metal thread mounting, Highly visible LEDs for Power ON and switching state Datash..
Thru-beam sensor (pair) M100/MV100-RT/35/76b/102/115
Thru-beam sensor, 20 m detection range, red light, light/dark on, DC version, NPN output, sensitivity adjuster, emitter switch-off, fixed cable, Miniature design, Easy to use, Very bright, highly visible light spot, Full metal thread mounting, Highly visible LEDs for Power ON and switching state Da..
Thru-beam sensor (pair) M100/MV100-RT/76a/103/115
Thru-beam sensor, 10 m detection range, red light, light/dark on, DC version, PNP output, sensitivity adjuster, emitter switch-off, fixed cable, Miniature design, Easy to use, Very bright, highly visible light spot, Full metal thread mounting, Highly visible LEDs for Power ON and switching state Da..
Thru-beam sensor (pair) M100/MV100-RT/76a/98/103
Thru-beam sensor, 10 m detection range, red light, light/dark on, DC version, PNP output, sensitivity adjuster, emitter switch-off, M8 plug, Miniature design, Easy to use, Very bright, highly visible light spot, Full metal thread mounting, Highly visible LEDs for Power ON and switching state Datash..
Thru-beam sensor (pair) M100/MV100-RT/76a/95/103
Thru-beam sensor, 10 m detection range, red light, light/dark on, DC version, PNP output, sensitivity adjuster, emitter switch-off, M8 plug, Miniature design, Easy to use, Very bright, highly visible light spot, Full metal thread mounting, Highly visible LEDs for Power ON and switching state Datash..
Thru-beam sensor (pair) M100/MV100-RT/76b/95/102
Thru-beam sensor, 10 m detection range, red light, light/dark on, DC version, NPN output, sensitivity adjuster, emitter switch-off, M8 plug, Miniature design, Easy to use, Very bright, highly visible light spot, Full metal thread mounting, Highly visible LEDs for Power ON and switching state Datash..
Thru-beam sensor (pair) M100/MV100-RT/76b/102/115
Thru-beam sensor, 10 m detection range, red light, light/dark on, DC version, NPN output, sensitivity adjuster, emitter switch-off, fixed cable, Miniature design, Easy to use, Very bright, highly visible light spot, Full metal thread mounting, Highly visible LEDs for Power ON and switching state Da..
Thru-beam sensor (pair) M100/MV100-IR/76a/95/103
Thru-beam sensor, 15 m detection range, infrared light, light/dark on, DC version, PNP output, sensitivity adjuster, emitter switch-off, M8 plug, Miniature design, Easy to use, Full metal thread mounting, Highly visible LEDs for Power ON and switching state, Not sensitive to ambient light Datasheet..
Thru-beam sensor (pair) M100/MV100-IR/76b/102/115
Thru-beam sensor, 15 m detection range, infrared light, light/dark on, DC version, NPN output, sensitivity adjuster, emitter switch-off, fixed cable, Miniature design, Easy to use, Full metal thread mounting, Highly visible LEDs for Power ON and switching state, Not sensitive to ambient light Datas..
Field-attachable male connector V35S-G-ABG
Cable connector, M9, 5-pin, shielded, field-attachable Datasheet excerpt: Technical data of V35S-G-ABG Product Description Cable connector, M9, 5-pin, shielded, field-attachable General specifications Number of pins5 Connection 1Male connector Construction type 1straight Th..
Control interface unit IC-KP2-1HB6-2V15B
Control interface unit IDENTControl Compact with interface for PROFIBUS DP Datasheet excerpt: Technical data of IC-KP2-1HB6-2V15B Product Description Control interface unit IDENTControl Compact with interface for PROFIBUS DP General specifications Number of read/write h..




