Thru-beam sensor (pair) LA31/LK31/31/115

Thru-beam sensor (pair) LA31/LK31/31/115

  • Brand:Pepperl+Fuchs
  • Product Code: LA31/LK31/31/115
  • Availability: Out Of Stock

Thru-beam sensor, 30 m detection range, red light, dark on, AC/DC version, relais output, fixed cable, Cost-optimized series for standard tasks, Large construction with small housing, Highly visible LED, Version for universal voltages, Relay output

Datasheet excerpt: Technical data of  LA31/LK31/31/115

Product Description
Thru-beam sensor, 30 m detection range, red light, dark on, AC/DC version, relais output, fixed cable
System components
EmitterLA31/115
ReceiverLK31/31/115
General specifications
Effective detection range0 ... 30 m
Threshold detection range43 m
Light sourceLED
Light typemodulated visible red light , 630 nm
Alignment aidLED yellow:
1. LED illuminates: Sufficient light signal received, emitter and receiver alignment is correct
2. LED flashes: Reaching switching point
3. LED off: Light beam is interrupted or the alignment is out
Diameter of the light spotapprox. 800 mm at a distance of 30 m
Opening angleEmitter: 0.5 ° , Receiver: 1.5 °
Ambient light limit50000 Lux ; according to EN 60947-5-2
Functional safety related parameters
MTTFd620 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED green: power on
Function indicatorLED yellow:
1. LED lit constantly: signal > 2 x switching point (function reserve)
2. LED flashes: signal between 1 x switching point and 2 x switching point
3. LED off: signal < switching point
Electrical specifications
Operating voltage24 ... 240 V AC
12 ... 240 V DC
No-load supply currentEmitter: ≤ 20 mA
Receiver: ≤ 20 mA
Power consumptionEmitter: ≤ 1 VA
Receiver: ≤ 1 VA
Output
Switching typedark-on
Signal outputRelay, 1 alternator
Switching voltagemax. 250 V AC/DC
Switching currentmax. 3 A
Switching powerDC: max. 150 W AC: max. 750 VA
Switching frequency≤ 20 Hz
Response time≤ 25 ms
Conformity
Product standardEN 60947-5-2
Compliance with standards and directives
Standard conformity
StandardsEN 62103
Approvals and certificates
Protection classII , rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit basis insulation of input circuit according to EN 50178, rated insulation voltage 240 V AC
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 55 °C (-13 ... 131 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Housing width18 mm
Housing height62 mm
Housing depth35 mm
Degree of protectionIP67
ConnectionEmitter: 2 m fixed cable , 2-wire
Receiver: 2 m fixed cable , 5-wire
Material
HousingPolycarbonate
Optical facePMMA
MassEmitter: 116 g
Receiver: 131 g

Classifications

SystemClasscode
ECLASS 13.027270901
ECLASS 12.027270901
ECLASS 11.027270901
ECLASS 10.0.127270901
ECLASS 9.027270901
ECLASS 8.027270901
ECLASS 5.127270901
ETIM 9.0EC002716
ETIM 8.0EC002716
ETIM 7.0EC002716
ETIM 6.0EC002716
ETIM 5.0EC002716
UNSPSC 12.139121528